The Microlab 300 is a true semi-automated clinical chemistry analyzer in all its glory. A system that is designed as a clinical chemistry analyzer and not as a standard photometer. Thousands of users have experienced the proven reliability and high performance of the Microlab all over the world. Robust, compact and easy-to-use, it is ideal for smaller or satellite laboratory locations. Together with a superior menu of ready-to-use, liquid-stable reagents, the Microlab 300 covers primary, STAT or back-up testing needs. This system offers minimal maintenance and effective use of consumables to provide a truly cost effective operation.

Semi-automated clinical chemistry analyzer
60 programmable tests
Broad test menu
Full size screen and qwerty keyboard
No warm up time
Easy-to-train, operate and maintain
Bi-directional host connection
Up to 12 programmable wavelengths
Delivering trouble-free results laboratories can trust!

Light Source Quartz-iodine lamp 12V-20W.
Wavelength Range
– Optical unit with 12 position filter wheel
– 340, 405, 505, 546, 578, 620 nm standard installed
– 6 positions for optional filters.
Photometric Range
-0.1 to 2.3 Absorbance
Resolution 0.001 Abs.
Detector
Photo diode (320-1000 nm).
Blanking
Automatic zero setting.
Operator Interface
– Membrane keyboard, for direct function and alpha-numeric entry
– Optional external keyboard
– High contrast graphical LCD display
– Real time clock, 24 hours system.
Measurement Procedures
– Kinetic measurement with linearity check
– Kinetic, with linearity check and sample slope blank
– Two point kinetic, with or without reagent blank
– End point, with or without reagent blank
– Bichromatic end point, with or without reagent blank
– End point, with sample blank and with or without reagent blank.
Multiple Testing
– Up to nine replicates
– Means, SD and CV.
Measurement Time
– Programmable, 2 to 998 seconds for kinetic and two point type of tests
– For end point fixed at 2 seconds.
Delay Time
Programmable, 0 to 999 seconds.
Parameter Setting
– Method name
– Measurement mode
– Wavelength 1 and 2
– Aspiration volume
– Measurement delay
– Measurement time
– Factor
– Concentration standards
– Reagent blank y/n
– Sample blank y/n
– Units for results
– Levels for flagging
– Curve fit y/n
– Linearity check.
Calibration
– Factor, one-point, two-point and multi-point
– Automatic on 1 standard (linear mode)
– Automatic on up to 10 standards (non-linear mode).
Quality Control
– Two controls per test
– QC survey of last 30 control measurements
– Levey Jenning plot
– High/low flags.
Flowcell
Metal, with quartz windows, measuring volume 30 µL.
Temperature Control
– By means of Peltier elements
– Fixed temperature at 37°C.
Aspirator System
– Internal pump of bellows type, driven by stepper motor:
– Back panel connection for waste
– Aspiration volume programmable.
Printer
– Internal matrix printer
– Normal paper
– External printer port available.
Signal Interface
– Centronics type parallel port
– RS 232 type serial port
– PS 2 type port for external keyboard.
Standards and Regulations
– CE -IVD
– CB
– UL.
Dimensions and Power Requirements
– 40 x 17 x 36,6 cm (W x H x D)
– Weight: 8,5 kg.
– 100-240 VAC nominal, 50/60 Hz
– Battery back-up to retain data

Processing Center

Optimized test environment ensures accurate results
Measurement takes place in a specially designed patented flowcell
Superior optical design
Temperature controlled, 37°C
Easy-to-train, operate and maintain
Interactive and intuitive testing
Built in printer
Built in quality control
Low maintenance required
Cover designed for maintenance purposes
Easy paper roll or parts replacement
Low volumes
Minimal water consumption
30 µL measuring volume
Password protection
Operator Interface

Easy-to-use
The simplicity of the software allows a skilled technician to operate the Microlab 300 within an hour. Interactive and intuitive routines lead the operator to the results quickly. The system maintenance instructions are integrated in the software.
Onboard Quality Control
QC results are stored in memory and are easily displayed on the screen. The software calculates the mean, standard deviation and coefficient of variation.
Patient Results
Retrieval of results becomes even simpler with the Microlab 300. A special evaluate patient menu gives the possibility to retrieve measured data very easily. Up to 100 patient result reports are automatically stored.
Host Connection
Bi-directional Host Connection allows the analyzer to download parameter settings, system parameters and software upgrades from the host computer and to transmit patient data to the data management system.

Selectra XL
Selectra XL

The power of proven quality.
Selectra ProM
Selectra ProM

Setting the new standard in BenchTop chemistry. Typical throughput is 180 tests per hour and up to 266 tests per hour including ISE.
Selectra ProS
Selectra ProS

Fully-featured, compact system with enhanced performance. Typical throughput is 140 tests per hour and up to 266 test per hour including ISE.
Selectra ProXS
Selectra ProXS

More than other entry-level systems in a cost effective package. Typical throughput is 75 tests per hour.